Parameter
Parameters Register
Refer to the parameter list
41000 to
0 to 999
(page 38) for the parameter
41999
names.
Terminal 2 frequency
C2(902)
41902
setting bias (frequency)
Terminal 2 frequency
42092
setting bias (analog value)
C3(902)
Terminal 2 frequency
43902
setting bias (terminal
analog value)
Terminal 2 frequency
125(903)
41903
setting gain (frequency)
Terminal 2 frequency
42093
setting gain (analog value)
C4(903)
Terminal 2 frequency
43903
setting gain (terminal
analog value)
Terminal 4 frequency
C5(904)
41904
setting bias (frequency)
Terminal 4 frequency
42094
setting bias (analog value)
C6(904)
Terminal 4 frequency
43904
setting bias (terminal
analog value)
Terminal 4 frequency
126(905)
41905
setting gain (frequency)
Terminal 4 frequency
42095
setting gain (analog value)
C7(905)
Terminal 4 frequency
43905
setting gain (terminal
analog value)
Alarm history
Register
Definition
40501
Alarm history 1
40502
Alarm history 2
40503
Alarm history 3
40504
Alarm history 4
40505
Alarm history 5
40506
Alarm history 6
40507
Alarm history 7
40508
Alarm history 8
Alarm code list
Data
Description
Data
H00
No alarm
H52
H10
OC1
H60
H11
OC2
H70
H12
OC3
H80
H20
OV1
H81
H21
OV2
H90
H22
OV3
H91
H30
THT
HA0
H31
THM
HA1
H40
FIN
HB0
H50
IPF
HB1
H51
UVT
HB2
Parameter Name
Read/write
Read/write
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read
Read
Read
Read
Read
Read
Description
Data
Description
ILF
HB3
PE2
OLT
HC0
CPU
BE
HC1
CTE
GF
HC2
P24
LF
HC4
CDO
OHT
HC5
IOH
PTC
HC6
SER
OPT
HC7
AIE
OP1
HF1
E.1
PE
HF6
E.6
PUE
HF7
E.7
RET
HFD
E.13
Communication operation and setting
Remarks
The parameter number + 41000 is the
register number.
The analog value (%) set to C3 (902) is read.
The analog value (%) of the voltage (current)
applied to the terminal 2 is read.
The analog value (%) set to C4 (903) is read.
The analog value (%) of the voltage (current)
applied to the terminal 2 is read.
The analog value (%) set to C6 (904) is read.
The analog value (%) of the current (voltage)
applied to the terminal 4 is read.
The analog value (%) set to C7 (905) is read.
The analog value (%) of the current (voltage)
applied to the terminal 4 is read.
Remarks
Being 2 bytes in length, the data is stored
as "H00
". The error code can be
referrred to in the low-order 1 byte.
Performing write using the register 40501
batch-clears the alarm history. Set any
value as data.