Communication operation and setting
No.
Item
8
All parameter clear
9
Parameters
10
Link parameter
11
extended setting
Second parameter
changing
12
(instruction code
HFF=1)
Refer to page 164 for data formats (A, A', B, B', C, D)
REMARKS
⋅ Set 65520 (HFFF0) as a parameter value "8888" and 65535 (HFFFF) as "9999".
⋅ For the instruction codes HFF, HEC and HF3, their values are held once written but cleared to zero when an inverter reset
or all clear is performed.
Example) When reading the C3 (Pr. 902) and C6 (Pr. 904) settings from the inverter of station No. 0
Computer Send Data
1)
ENQ 00 FF 0 01 82
2)
ENQ 00 EC 0 01 7E
3)
ENQ 00 5E 0 0F
4)
ENQ 00 60 0 FB
To read/write C3 (Pr. 902) and C6 (Pr. 904) after inverter reset or parameter clear, execute from 1) again.
170
Read
Instruction
/write
Code
All parameters return to the initial values.
Any of four different all clear operations are performed
according to the data.
Pr.
Data
H9696
H9966
Write
HFC
H5A5A
H55AA
When all parameter clear is executed for H9696 or H9966,
communication-related parameter settings also return to
the initial values. When resuming operation, set the
parameters again.
*1
Refer to page 161, 162.
*2
Refer to page 129.
*3
Pr. 75 is not cleared
H00 to
Read
H63
Refer to the instruction code of the parameter list (page38)
and write and/or read the values as required.
H80 to
Write
HE3
Parameter description is changed according to the H00 to
Read
H7F
H09 setting.
For details of the setting, refer to the instruction code of the
Write
HFF
parameter list (page 38).
When setting the bias/gain (instruction codes H5E to H61,
HDE to HE1) parameters
Read
H6C
H00:Frequency
H01: Parameter-set analog value
H02: Analog value input from terminal
Write
HEC
*1
The gain frequency can also be written using Pr. 125
(instruction code H99) or Pr. 126 (instruction code H9A).
Inverter Send Sata
ACK 00
Set "H01" to the extended link parameter.
ACK 00
Set "H01" to second parameter changing.
STX 00 0000 ETX 25
C3 (Pr. 902) is read. 0% is read.
STX 00 0000 ETX 25
C6 (Pr. 904) is read. 0% is read.
Data Description
Communi-
Calibration
Other Pr.
cation Pr.
Pr.
*2
*1
×
×
×
×
*1
Description
Number of
Data Digits
(format)
HEC
HF3
*3
HFF
4 digits
(A,C/D)
4 digits
(B.E/D)
4 digits
(A,C/D)
2digits
(B.E'/D)
2digits
(A',C/D)
2digits
(B.E'/D)
2digits
(A',C/D)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents