Energy saving operation and energy saving monitor
(1) Energy saving monitor list
⋅ The following provides the items that can be monitored by the power saving monitor (Pr. 52, Pr. 54, Pr. 158 = "50").
(Only 1) Power saving and 3) Power saving average value can be output to Pr. 54 (terminal CA) and Pr. 158
(terminal AM))
Energy Saving
Monitor Item
1)
Power saving
2)
Power saving rate
Power saving
3)
average value
Power saving rate
4)
average value
Power savings
5)
amount average
value
⋅ The following shows the items which can be monitored by the cumulative saving power monitor (Pr. 52 = "51").
Energy saving
monitor item
Power saving
6)
amount
Power saving
7)
amount charge
Annual power
8)
saving amount
Annual power
9)
saving amount
charge
*1
For communication (RS-485 communication, communication option), the display increments are 1. For example, the communication data is
"10" for "10.00kWh".
*2
When using the parameter unit (FR-PU04), "kW" is displayed.
*3
The setting depends on capacities. (01160 or less/01800 or more)
REMARKS
⋅ As the operation panel (FR-DU07) is 4-digit display, it displays in 0.1 increments since a carry occurs, e.g. "100.0", when a
monitor value in 0.01 increments exceeds "99.99". The maximum display is "9999".
⋅ As the operation panel (FR-PU04) is 5-digit display, it displays in 0.1 increments since a carry occurs, e.g. "1000.0", when a
monitor value in 0.01 increments exceeds "999.99". The maximum display is "99999".
⋅ The upper limit of communication (RS-485 communication, communication option) is "65535" when Pr. 898 Power saving
cumulative monitor clear = "9999". The upper limit of 0.01 increments monitor is "655.35" and that of 0.1 increments monitor
is "6553.5".
120
Description and Formula
Difference between the estimated value of power
necessary for commercial power supply operation
and the input power calculated by the inverter
Power during commercial power supply
operation − input power monitor
Ratio of power saving on the assumption that power
during commercial power supply operation is 100%
1) Power saving
Power during commercial
power supply operation
Ratio of power saving on the assumption that
Pr. 893 is 100%
1) Power saving
× 100
Pr.893
Average value of power saving amount per
hour during predetermined time (Pr. 897)
Σ ( 1) Power saving × ∆t)
Pr.897
Ratio of power saving average value on the
assumption that the value during commercial
power supply operation is 100%
Σ ( 2) Power saving rate × ∆t)
Pr.897
Ratio of power saving average value on the
assumption that Pr. 893 is 100%
3) Power saving average value
Pr.893
Power saving average value represented in
terms of charge
3) Power saving average value × Pr. 896
Description and Formula
Power saving is added up per hour.
Σ ( 1) Power saving × ∆t)
Power saving amount represented in terms of charge
6) Power saving amount × Pr. 896
Estimated value of annual power saving amount
6) Power saving amount
Operation time during
Annual power saving amount represented in
terms of charge
8) Annual power saving amount × Pr. 896
Unit
0.01kW/
0.1kW
× 100
0.1%
0.01kW/
0.1kW
× 100
0.1%
× 100
0.01/0.1
*3
Unit
0.01kWh
/0.1kWh
*1*2*3
0.01/0.1
*1*3
0.01kWh
Pr.899
/0.1kWh
× 24 × 365 ×
100
*1*2*3
0.01/0.1
*1*3
Parameter Setting
Pr.895
Pr.896
Pr.897
9999
*3
9999
0
1
9999
*3
0
9999
0 to
1000h
1
0 to
500
Parameter Setting
Pr.895
Pr.896
Pr.897
9999
0 to
500
9999
0 to
500
Pr.899
Pr.899
9999
0 to
100%