Types of Monitor
Increments
0.01kW
Power saving effect
0.1kW *
PID set point
PID measurement value
* The setting depends on capacities. (01160 or less/01800 or more)
(2) Frequency monitoring reference(Pr. 55)
(10VDC)
(20mADC)
1Hz
50Hz
(initial value)
Setting range of Pr. 55
(3) Current monitoring reference (Pr. 56)
(10VDC)
(20mADC)
Rated output current
(initial value)
Setting range of Pr. 56
(4) Terminal AM response adjustment (Pr.867)
• Using Pr. 867, the output voltage response of the terminal AM can be adjusted within the range 0 to 5s.
• Increasing the setting stabilizes the terminal AM output more but reduces the response level. (Setting "0" sets
the response level to 7ms)
(5) Adjustment of response level of terminal CA (Pr.869)
• The response level of the output current of the terminal CA can be adjusted between 0 and 5s with Pr. 869.
• Increasing the setting stabilizes the terminal CA output more but reduces the response level. (Setting "0" sets
the response level to about 7ms.)
♦ Parameters referred to ♦
Pr. 37 Speed display
Refer to page 99
Pr.54 (CA)
Pr.158 (AM)
Full Scale Value
Setting
/
50
Inverter capacity
0.1%
52
100%
0.1%
53
100%
• Set the frequency to be referenced when the frequency monitor
(output frequency/set frequency) is selected for the terminal CA
and terminal AM display.
• Set the frequency when the current output at terminal CA is
20mADC.
The analog current output and inverter output frequency at
terminal CA are proportional. (The maximum output current is
20mADC.)
400Hz
• Set the frequency (output frequency/set frequency) when the
voltage output at terminal AM is 10VDC.
The analog voltage output and frequency at terminal AM are
proportional. (The maximum output voltage is 10VDC.)
• Set the current to be referenced when the current monitor
(inverter output current, etc.) is selected for the terminal CA and
terminal AM display.
• Set the current value when the current output at terminal CA is
20mADC.
The analog current output and current value at terminal CA are
proportional. (The maximum output current is 20mADC.)
• Set the current value when the voltage output at terminal AM is
500A
10VDC.
(3600A)
The analog voltage output and current value at terminal AM are
proportional. (The maximum output voltage is 10VDC.)
Monitor display and monitor output signal
Description
Displays the energy-saving effect monitor.
Power saving and power saving average value
are displayed according to parameters.
(Refer to page120 for details)
Displays the set value and process value for PID
control. (Refer to page 184 for details)