Function-Group Types
6.5 Function-Group Type Analog Units
Addr.
_:110
6.5.6.6

Information List

No.
MT in #
_:302
_:306
6.5.7

RTD Unit Ethernet

6.5.7.1

Overview

The RTD unit Ether. function:
Communicates with an external RTD unit via the Slave Unit Protocol (SUP) and records the measured
temperatures from the RTD unit
Provides the captured temperatures to the temperature monitoring function
Monitors communication with the RTD unit
6.5.7.2

Structure of the Function

The RTD unit Ether. function can only work in the Analog units function group. A maximum of 20 function
instances can work simultaneously. Each instance contains 12 preconfigured sensor function blocks.
[dwstrfnc-291112-01.tif, 2, en_US]
Figure 6-56
196
Parameter
MT in #:Lower limit -
Sensor
Information
MT in #:TD scale MV
MT in #:TD scale SAV
Structure/Embedding of the Function
C
Setting Options
-1000000.00 to 1000000.00
Default Setting
1.00
Data Class
Type
(Type)
MV
O
SAV
O