Table 12- 4
Comparison of the connection versions
Var. Module width
[mm]
1
50 ... 100
2
50 ... 100
3
50 ... 100
4
150
5
150 ... 300
6
200 ... 300
Connections as cross-sectional drawings (view from below)
Note
The different connection versions of the DC-link adapter are shown in the following cross-
sectional drawings. Special features are highlighted in bold in the table above.
Variant 1: Module width 50-100 mm, connected to the drive line-up from the right, standard DC-link
busbar
Figure 12-5
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
Installat
Current-
ion
carrying
capacity of
the
DC-link
busbar [A]
Right
≤ 100
Right
≤ 150
Left
≤ 100
Right
≤ 150
Left
≤ 150
Right
≤ 200
DC-link adapter 6SL3162-2BM01-0AA0 (4 hole)
Standard DC-link busbar (4 mm)
Connecting the DC-link adapter to the module using 2 M4x20 screws
Connecting the DC-link busbar to the module using 2 M4x16 screws
DC-link bridge
Variant 1 (representation from below)
12.5 Arrangement of components and equipment
DC-link
DC-link
adapter
busbar
6SL3162-...
2BM01-0AA0 Standard
2BM10-0AA0 Reinforced 2 screws
2BM01-0AA0 Standard
2BM01-0AA0 Standard
2BM01-0AA0 Standard
2BM01-0AA0 Standard
Cabinet design and EMC Booksize
Fastening of the
Screws
DC-link adapter
to two DC-link
busbars
2 screws
M4x20
M4x20
2 screws
M4x16
2 screws
M4x20
2 screws
M4x20
4 screws
M4x20
Washers
No
No
No
No
Yes
No
703