Configuration Instructions - Siemens Sinamics S120 Manual

Booksize power units
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Table 8- 6
Duty cycles
Short duty cycle
A [s]
0,1
T [s]
11,5
The following applies when connecting Braking Modules in parallel:
P
N total
P
max total
8.2.9

Configuration instructions

DC link capacitance
To operate the Braking Modules, a minimum capacitance is required in the DC link. The DC
link capacitance for each braking resistor is 440 μF.
The capacitance of the Braking Module of 110 µF is included in the total capacitance value.
Note
Only the components that are connected to each other via the DC link busbar can be
included in the total capacitance.
DC link cable
In a two-row or distributed drive line-up, the DC links are connected to each other via a DC
link cable. When using a Braking Module in the drive line-up, this cable must not be longer
than 10 m. The DC link cable must be twisted and have a minimum cross-section of at least
10 mm
Parallel connection
The Braking Module Booksize Compact 6SL3400-1AE31-0AAx is recommended for the
parallel connection of Braking Modules.
Parallel connection of the Braking Module 6SL3100-1AE31-0AAx is not recommended
because a power distribution between the modules is not guaranteed.
Note
When Braking Modules are connected in parallel, the DC link capacitance specified above
must be available for each Braking Module.
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
6SN1113–1AA00–0DA0
Long duty cycle
0,4
210
= 0.9 x total P
of single devices
N
= total P
of single devices
max
.
2
8.2 Braking Module Booksize
6SL3100–1BE31–0AAx
Short duty cycle
1
68
DC link components
Long duty cycle
2
460
527