Meaning Of Leds - Siemens Sinamics S120 Manual

Booksize power units
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Note
The digital inputs DI are isolated and refer to M_DI (X21.5 and X21.6).
The reference point of the digital outputs DO is the ground GND of the 24 V supply.
To parameterize the digital inputs or digital outputs, see the SINAMICS S120/S150 List
Manual.
8.3.5

Meaning of LEDs

Table 8- 13
Meaning of LEDs on the Braking Module Booksize Compact
LED
Color
Status
READY
-
Off
Green
Continuous
light
Red
Continuous
light
DC LINK
-
Off
Orange
Continuous
light
Orange
Flashing
light
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
Description
The electronics power supply is missing or outside the
permissible tolerance range.
The component is ready for operation.
Enable missing (input terminal)
Overtemperature of IGBT/braking resistor
Overcurrent trip
I
t monitoring activated
2
Braking power monitoring triggered
Ground fault/short circuit
Note:
In the event of overtemperature, l
braking power monitoring, the fault will be
acknowledged automatically after a cooling down
phase. Manual acknowledgment is not possible.
The DC link voltage is not available, the electronics
power supply is missing or is outside the permissible
tolerance range.
The component is not active.
The DC link voltage is present.
The component is active. The DC link is being
discharged via the braking resistor.
8.3 Braking Module Booksize Compact
Remedy
Check the electronics power
supply.
-
Troubleshoot the fault using
the output terminals and
acknowledge it using the
input terminal.
t monitoring or
2
-
-
DC link components
537

Advertisement

Table of Contents
loading

Table of Contents