Reinforced Dc Link Busbars; Description - Siemens Sinamics S120 Manual

Booksize power units
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Accessories

11.3 Reinforced DC link busbars

11.3
Reinforced DC link busbars
11.3.1

Description

Reinforced DC-link busbars are available for 50 mm and 100 mm wide components of the
Booksize and Booksize Compact series. They are used to increase the current carrying
capacity of the components used to conduct the DC-link current from 100 A to 150 A.
Table 11- 11 Reinforced DC-link busbars
Reinforced DC-link busbars
Suitable for 50 mm components
Suitable for 100 mm components
Notes on configuration and arrangement of the components in the drive line-up can be found
in the Chapter, Arrangement of components and devices (Page 696).
Note
DC-link rectifier adapter / DC-link adapter
The following must be taken into account when using reinforced DC-link busbars:
• It is not possible to use a DC-link rectifier adapter!
• Use DC-link adapter 6SL3162-2BM10-0AA0 (2-hole adapter).
646
Order number
6SL3162-2DB00-0AAx
6SL3162-2DD00-0AAx
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6

Advertisement

Table of Contents
loading

Table of Contents