Double Motor Modules - Siemens Sinamics S120 Manual

Booksize power units
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

6.4.7.2

Double Motor Modules

Table 6- 44
Technical data Double Motor Modules (2 x 3 to 2 x 18 A)
Cold plate
Output current
Rated current (I
)
n
Base-load current (I
)
H
Intermittent duty current (I
Peak current (I
)
max
Output voltage
DC-link current I
d max
DC-link voltage
DC-link capacitance
Overvoltage trip
Undervoltage trip
2)
Electronics power supply
Electronics current drawn
at 24 VDC
Current carrying capacity
DC-link busbars
Reinforced DC-link busbars
24 VDC busbars
Unit rating
3)
Based on I
(600 VDC; 4 kHz)
n
Based on I
H
Total power loss
(including electronics losses, see Power
loss tables (Page 781))
Max. pulse frequency
without derating
with derating
Max. ambient temperature
without derating
with derating
Max. permissible heat sink temperature
Weight
Applies only to order numbers with x = 0 .. 3
1)
Default for 400 V line systems; undervoltage trip threshold can be reduced by up to 80 V and is adjusted to the
2)
parameterized rated voltage
Rated power of a typical standard induction motor at 400 V 3 AC.
3)
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
6SL3126- 2TE13-0AAx
A
ACrms
A
) 40%
A
S6
ACrms
A
ACrms
V
ACrms
A
DC
V
DC
μF
V
DC
V
DC
V
DC
A
DC
A
DC
A
DC
A
DC
kW
kW
W
kHz
kHz
° C
° C
° C
kg
2TE15-0AAx
1)
2 x 3
2 x 5
2 x 2.6
2 x 4.3
2 x 3.5
2 x 6
2 x 6
2 x 10
7,2
12
110
220
24 (20,4 ... 28,8)
0,9
0,9
100
100
150
150
20
20
2 x 1.6
2 x 2.7
2 x 1.4
2 x 2.3
91,6
126,6
80
80
4,5
4,5
Motor Modules Booksize
6.4 Motor Modules with cold plate
2TE21-0AAx
2TE21-8AAx
1)
1)
2 x 9
2 x 18
2 x 7.7
2 x 15.3
2 x 10
2 x 24
2 x 18
2 x 36
0 ... 480
22
43
510 ... 720
220
705
820 ± 2 %
380
0,9
1,05
100
100
150
150
20
20
2 x 4.8
2 x 9.7
2 x 4.1
2 x 8.2
181,6
345,2
4
16
40
55
90
90
4,5
5,9
459

Advertisement

Table of Contents
loading