NEC SL 1000 Programming Manual page 536

Hide thumbs Also See for SL 1000:
Table of Contents

Advertisement

SL1000/SL1100
Alarm
No.
30
Program
31
90
32
50
51
54
55
57
2-514
Downloaded from
www.Manualslib.com
Re-
Type
Name
port
2
0
SMDR Buf-
The temporary buf-
fer full
fer for SMDR in
main device over-
flowed, and a part
of output SMDR
data disappeared
because it could
not output SMDR
1
0
Security
Sensor detected
Sensor
detected
1
0
Automatic
Remote watch
Transmis-
function did auto
sion from
Remote
Surveil-
lance
1
0
System
The system started.
Start Notifi-
cation
0
0
System
CPU Upgrade is
Data
performed or Pro-
change
gramming change
2
0
License
A new TCP/IP ter-
Manage-
minal and the DSP
ment Table
board were not able
Full
to be added to the
application license
management table.
• The license
2
0
Regular
The regular mainte-
mainte-
nance exchange
nance ex-
day has passed.
change
notification.
2
0
IP Collision
Check the IP Ad-
error
dress collision
(CPU, VOIPDB,
Program 84-26-01
manuals search engine
Content of
Cause
Alarm
1 Problem of wir-
ing to connect
main device
with PC.
2 PC Problem.
data.
Sensor detected
abnormality.
abnormality.
Remote watch
function did auto
dialing.
dialing.
The system was
started.
is made.
Maximum 512 li-
cense information
on the TCP/IP ter-
minal is regis-
tered, and a new
terminal cannot be
registered.
management
table is register-
ing full.
• The regular
maintenance
exchange day
that had been
set with Pro-
gram 90-51
exceeded it.
Collision IP Ad-
dress in the net-
work.
GW : 1 ~ 8).
Program 90 : Maintenance Program
ISSUE 1.0
Action
Recovery
1 Confirm
When the
whether there is
output is
problem in wir-
restarted,
ing to connect a
the error is
main device
recovered.
with PC.
However,
2 Execute the
the SMDR
reactivation of
data after
PC.
the error
occurs is not
recorded.
Especially, any-
thing need not be
done.
Especially, any-
thing need not be
done.
No action needed.
No action needed.
Please delete li-
cense information
on an unnecessary
TCP/IP terminal
with Program 90-
44.
Please do the
The excess
maintenance ex-
on the regu-
changes of perti-
lar mainte-
nent parts, and set
nance
the next regular
exchange
maintenance ex-
day is can-
change day with
celed by
Program 90-51.
changing
Program
90-51 or
when the
function is
invalidated,
the error is
recovered.
Check the IP Ad-
Recover the
dress in the net-
IP Address
work.
collision.
Alarm
Status
ERR
REC
INF
INF
WAR
ERR
REC
WAR

Hide quick links: