Program 14 : Trunk, Basic Setup; Basic Trunk Data Setup - NEC SL 1000 Programming Manual

Hide thumbs Also See for SL 1000:
Table of Contents

Advertisement

ISSUE 1.0
Level
IN
Description
Use Program 14-01 : Basic Trunk Data Setup to set the basic options for each trunk port. Refer to
the chart below for a description of each option, its range and default setting.
Input Data
Item
No.
01
02
03
04
05
06
07
08
Programming Manual
Downloaded from
www.Manualslib.com

Program 14 : Trunk, Basic Setup

Trunk Port Number
Item
Trunk Name
Set the names for trunks. The
trunk name displays on a multi-
line terminal for incoming and
outgoing calls.
Transmit Level
Use this option to select the
CODEC gain for the trunk. The
option sets the gain (signal am-
plification) for the trunk you are
programming.
Receive Level
Use this option to select the
CODEC gain for the trunk. The
option sets the gain (signal am-
plification) for the trunk you are
programming.
Transmit Gain Level for Con-
ference and Transfer Calls
Use this option to select the
CODEC gain type used by the
trunk when it is part of an Unsu-
pervised Conference.
Receive Gain Level for Confer-
ence and Transfer Calls
Use this option to select the
CODEC gain type used by the
trunk when it is part of an Unsu-
pervised Conference.
SMDR Printout
Use this option to have the sys-
tem include/exclude the trunk
you are programming from the
SMDR printout. Refer to Pro-
grams 35-01 and 35-02 for
SMDR printout options.
Outgoing Calls
Use this option to allow/prevent
outgoing calls on the trunk you
are programming.
Toll Restriction
Use this option to enable/
disabled Toll Restriction for the
trunk. If enabled, the trunk fol-
lows Toll Restriction program-
ming (example: Programs 21-05,
21-06). If disabled, the trunk is a
toll free line.
manuals search engine

14-01 : Basic Trunk Data Setup

Input Data
Default
Up to 12 characters
Refer below
1 ~ 63
32 (0 dB)
(- 15.5 dB ~ + 15.5
dB in 0.5 dB inter-
vals)
1 ~ 63
32 (0 dB)
(- 15.5 dB ~ + 15.5
dB in 0.5 dB inter-
vals)
1 ~ 63
32 (0 dB)
(- 15.5 dB ~ + 15.5
dB in 0.5 dB inter-
vals)
1 ~ 63
16 (- 8 dB)
(- 15.5 dB ~ + 15.5
dB in 0.5 dB inter-
vals)
0 = No Print Out
1
1 = Prints Out
0 = Deny (No)
1
1 = Allow (Yes)
0 = Restriction Dis-
1
abled (No)
1 = Restriction En-
abled (Yes)
SL1000/SL1100
001 ~ 126 (SL1000)
001 ~ 096 (SL1100)
Related Program
Note
21-04
21-05
21-06
Program
14
2-97

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl 1100

Table of Contents