Parameter Description
P2002[3]
Reference current
CStat:
CT
P-Group: COMM
Full-scale output current used over serial link (corresponds to 4000H).
Index:
P2002[0] : 1st. Drive data set (DDS)
P2002[1] : 2nd. Drive data set (DDS)
P2002[2] : 3rd. Drive data set (DDS)
Example:
If a BICO connection is made between two parameters, the "unit" of the parameters (standardized (Hex) or
physical (i.e. A) values) may differ. MICROMASTER implicitly makes an automatic conversion to the target
value.
r0027
x[A]
P2003[3]
Reference torque
CStat:
CT
P-Group: COMM
Full-scale reference torque used over the serial link (corresponds to 4000H).
Index:
P2003[0] : 1st. Drive data set (DDS)
P2003[1] : 2nd. Drive data set (DDS)
P2003[2] : 3rd. Drive data set (DDS)
Example:
If a BICO connection is made between two parameters or alternatively using P1500, the "unit" of the
parameters (standardized (Hex) or physical (i.e. Nm) values) may differ. MICROMASTER implicitly makes
an automatic conversion to the target value.
r0080
x[Nm]
P2004[3]
Reference power
CStat:
CT
P-Group: COMM
Full-scale reference power used over the serial link (corresponds to 4000H).
1
=
⋅
⋅
r2004
2
2
Index:
P2004[0] : 1st. Drive data set (DDS)
P2004[1] : 2nd. Drive data set (DDS)
P2004[2] : 3rd. Drive data set (DDS)
Example:
If a BICO connection is made between two parameters, the "unit" of the parameters (standardized (Hex) or
physical (i.e. kW / hp) values) may differ. MICROMASTER implicitly makes an automatic conversion to the
target value.
r0032
x[kW]
or
x[hp]
depending on P0100
194
Datatype: Float
Active: first confirm
P2016
[0]
USS-PZD
[1]
BOP link
[2]
[3]
y[Hex]
Datatype: Float
Active: first confirm
P2051
[0]
CB-PZD
[1]
COM link
[2]
[3]
y[Hex]
Datatype: Float
Active: first confirm
⋅ π
⋅
=
⋅ π
⋅
f
M
P2000
P2003
P2019
[0]
USS
[1]
COM link
[2]
[3]
y[Hex]
Min:
0.10
Unit: A
Def:
0.10
QuickComm.: No
Max:
10000.00
r0027[A]
=
⋅
y[Hex]
4000
[
Hex
]
P2002[A]
Min:
0.10
Unit: Nm
Def:
0.12
QuickComm.: No
Max:
99999.00
r0080[Nm]
=
⋅
y[Hex]
4000
[
Hex
P2003[Nm]
Min:
0
Unit: -
Def:
QuickComm.: No
Max:
0
r0032
=
⋅
y[Hex]
4000
[
Hex
]
r2004
MICROMASTER 440
6SE6400-5BB00-0BP0
Issue 01/06
Level
3
Level
3
]
Level
3
Parameter List