Parameter Description
P2212[3]
Fixed PID setpoint 12
CStat:
CUT
P-Group: TECH
Defines Fixed PID Setpoint 12
Index:
P2212[0] : 1st. Drive data set (DDS)
P2212[1] : 2nd. Drive data set (DDS)
P2212[2] : 3rd. Drive data set (DDS)
Details:
See P2201 (Fixed PID Setpoint 1).
P2213[3]
Fixed PID setpoint 13
CStat:
CUT
P-Group: TECH
Defines Fixed PID Setpoint 13
Index:
P2213[0] : 1st. Drive data set (DDS)
P2213[1] : 2nd. Drive data set (DDS)
P2213[2] : 3rd. Drive data set (DDS)
Details:
See P2201 (Fixed PID Setpoint 1).
P2214[3]
Fixed PID setpoint 14
CStat:
CUT
P-Group: TECH
Defines Fixed PID Setpoint 14
Index:
P2214[0] : 1st. Drive data set (DDS)
P2214[1] : 2nd. Drive data set (DDS)
P2214[2] : 3rd. Drive data set (DDS)
Details:
See P2201 (Fixed PID Setpoint 1).
P2215[3]
Fixed PID setpoint 15
CStat:
CUT
P-Group: TECH
Defines Fixed PID Setpoint 15
Index:
P2215[0] : 1st. Drive data set (DDS)
P2215[1] : 2nd. Drive data set (DDS)
P2215[2] : 3rd. Drive data set (DDS)
Details:
See P2201 (Fixed PID Setpoint 1).
P2216[3]

Fixed PID setpoint mode - Bit 0

CStat:
CT
P-Group: TECH
Fixed frequencies for PID setpoint can be selected in three different modes. Parameter P2216 defines the
mode of selection Bit 0.
Possible Settings:
1
Direct selection
2
Direct selection + ON command
3
Binary coded selection + ON command
Index:
P2216[0] : 1st. Command data set (CDS)
P2216[1] : 2nd. Command data set (CDS)
P2216[2] : 3rd. Command data set (CDS)
P2217[3]

Fixed PID setpoint mode - Bit 1

CStat:
CT
P-Group: TECH
BCD or direct selection Bit 1 for PID setpoint.
Possible Settings:
1
Direct selection
2
Direct selection + ON command
3
Binary coded selection + ON command
Index:
P2217[0] : 1st. Command data set (CDS)
P2217[1] : 2nd. Command data set (CDS)
P2217[2] : 3rd. Command data set (CDS)
226
Datatype: Float
Unit: %
Active: Immediately
QuickComm.: No
Datatype: Float
Unit: %
Active: Immediately
QuickComm.: No
Datatype: Float
Unit: %
Active: Immediately
QuickComm.: No
Datatype: Float
Unit: %
Active: Immediately
QuickComm.: No
Datatype: U16
Unit: -
Active: first confirm
QuickComm.: No
Datatype: U16
Unit: -
Active: first confirm
QuickComm.: No
Issue 01/06
Min:
-200.00
Def:
110.00
Max:
200.00
Min:
-200.00
Def:
120.00
Max:
200.00
Min:
-200.00
Def:
130.00
Max:
200.00
Min:
-200.00
Def:
130.00
Max:
200.00
Min:
1
Def:
1
Max:
3
Min:
1
Def:
1
Max:
3
MICROMASTER 440
Parameter List
6SE6400-5BB00-0BP0
Level
2
Level
2
Level
2
Level
2
Level
3
Level
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents