ABB PSTX30 Installation And Commissioning Manual page 118

Hide thumbs Also See for PSTX30:
Table of Contents

Advertisement

Parameter
Description
number
11
External IO
11.01
1DI0 function
11.02
1DI1 function
11.03
1DI2 function
11.04
1DI3 function
11.05
1DI4 function
11.06
2DI5 function
11.07
2DI6 function
11.08
2DI7 function
11.09
1DO0 function
11.10
1DO1 function
7
11.11
2DO2 function
11.12
2DO3 function
11.13
1AO0 reference
11.14
1AO0 type
11.15
1AO0 max value
11.16
1AO0 min value
12
Communication
12.01
Com3 function
12.02
FB interface connector
12.03
Fieldbus control
12.04
Fieldbus address
12.05
Fieldbus IP address
12.06
Fieldbus IP gateway
12.07
Fieldbus IP netmask
12.08
Fieldbus IP DHCP client
12.09
FB baud rate
12.10
FB parity
12.11
FB stop bits
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Setting range
None, Reset, Enable, Slow speed forward,
Slow speed reverse, Motor heating, Stand still
brake, Start reverse, User defined protection,
Emergency mode, Fieldbus disable control,
Start 1, Start 2, Start 3 ***
0 ... 15 ***
0 ... 15 ***
None, Reset, Enable, Slow speed forward,
Slow speed reverse, Motor heating, Stand still
brake, Start reverse, User defined protection,
Emergency mode, Fieldbus disable control,
Start 1, Start 2, Start 3 ***
0 ... 15 ***
0 ... 15 ***
0 ... 15 ***
0 ... 15 ***
None, Run, Top of ramp, Event group 0,
Event group 1, Event group 2, Event group 3,
Event group 4, Event group 5, Event group 6,
Sequence 1 Run, Sequence 2 Run,
Sequence 3 Run, Sequence 1 TOR, Sequence
2 TOR, Sequence 3 TOR ****
0 ... 15 *** *
0 ... 15 *** *
0 ... 15 *** *
0-10 mA, 0-20 mA, 4-20 mA, 0-10 V
Motor current [A], Mains voltage [V], Active
power [kW], Active power [HP], Reactive power
[kVAr], Apparent power [kVA], Active energy
[kWh], Reactive energy [kVArh], COS [θ], Motor
temperature [%], Thyristor temperature [%],
Motor voltage [%]
Mains frequency [Hz], PT100 temperature
[centigrade], PTC resistance [Ω]
0 ... 1000000
0 ... 1000000
None, Test, Modbus RTU slave. Extension I/O
FbPlug, Modbus RTU, Anybus, None
On / Off
0 ... 65535
000.000.000.000
000.000.000.000
255.255.255.000
On / Off
1200, 2400, 4800, 9600, 19200, 38400,
57600, 76800, 115200, 125000, 250000,
500000, auto
No parity, Odd parity, Even parity
1 Stop bit, 2 Stop bits
Number of
Fieldbus
Default value
decimal
ID
0
145
None
0
146
None
0
147
None
0
148
None
0
149
None
0
150
None
0
151
None
0
152
None
0
153
4-20 mA
0
154
None
0
155
None
0
156
None
0
157
4-20 mA
0
158
Motor current
[A]
0
159
500
0
160
0
0
26
Test
0
32
None
0
45
Off
0
51
0
0
58
0
0
59
0
0
83
4294967040u
0
92
Off
0
185
19200
0
136
Even parity
0
141
1 Stop bit
Actual
setting