Server - NEC Express5800 Maintenance Manual

Hide thumbs Also See for Express5800:
Table of Contents

Advertisement

Chapter 2 Convenient Features

1.2.4 Server

If you move the cursor to Server, the Server menu screen appears. For the menu that has
the cursor to it and then press the <Enter> key to show its submenus.
The Server menu screen shows the options you can configure and their features. For the menu System
Management, move the cursor to it and then press the <Enter> key to show its submenus.
Option
System Management
Power Control Configuraiton
POST Monitoring
Boot Monitoring
Boot Monitoring Time
OpROM Monitoring
FailFlow Monitor
FailFlow Monitor Time
Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide
Parameter
[Enabled]
Specify how the system should operate if POST error
Disabled
occurred.
[Disabled]
Enable or disable the boot monitoring feature.
Enabled
To use this feature, NEC ESMPRO Agent must be
installed on OS. If starting up an OS on which it is not
installed, disable this feature.
Number
Specify boot monitoring timeout. Allowable value is
between 1 and 60 minutes. This item is displayed only
when Boot Monitoring is set to Enabled. When Boot
Monitoring is set to Enabled, the default value is 1
minute.
[Disabled]
Enable or disable the feature to monitor timeout of
Enabled
OpROM stall.
[Disabled]
Specify whether the server is automatically rebooted
Enabled
after fatal error occurred.
Number
Specify timeout monitoring time at occurrence of fatal
error. Allowable value is between 1 and 60 minutes.
This item is displayed only when FailFlow Monitor is set
to Enabled. When FailFlow Monitor is set to Enabled,
the default value is 30 minutes.
on the left, move
Descriptions
1. System BIOS