The following is a list of the XSeries
location and connections and enclosure type.
Electronic board
LCD assembly
Lithium battery
12 V battery
Complete XIMV assembly (Transducer)
Serial communication modules (RS-232 and RS-485)
Figure 10-22: Exploded view of an XSeriesG5 enclosure
computer, which will assist with disassembly and reassembly.
Figure 10-22: Exploded view of an XSeries
Table 10-2: Exploded view Legend
Number
Part name
1
Enclosure
2
MMI connector
3
Door
10.7.1
Replace the 12 Vdc battery
These instructions describe the removal and replacement of the 12 Vdc battery.
NOTICE – Loss of data: Do not remove the lithium battery from the electronic board when
removing the 12 Vdc battery. The lithium battery keeps the real-time clock running.
1 1 6 | XSE RIE S G5 | 2 10 60 2 6MNAA
G5
replaceable parts. Part removal method depends on the part
G5
enclosure
Number Part Name
4
Battery tray
5
Door latch
6
LCD
shows an exploded view of the XSeries
Number Part Name
7
Lithium battery
8
Electronic board to
transducer cable
9
Transducer housing
G5