Figure 8-13: Verify The Communications Set Up For Comm1 - ABB XRC G5 User Manual

Hide thumbs Also See for XRC G5:
Table of Contents

Advertisement

Table 8-3: Communication setup parameters
Timeouts and delays
Parameter
Ack timeout (s)
Response delay (ms)
Xmit key delay (ms)
Unkey delay (ms)
Power up delay (ms)
For RS-485 communication, position the termination jumpers according to the following
table:
Table 8-4: RS-485 Termination on COMM1
Position of the device on the Bus
Last or only unit
Intermediate
Click Send changes to device after all values have been set.
Observe the LCD on the enclosure door. The annunciator in position A8 should periodically flash the
symbol to indicate that the COMM1 port is active and listening for communication. See the following
figure.

Figure 8-13: Verify the communications set up for COMM1

Scroll area
Battery Voltage
14.3 VOLTS
Value
Display
description
IMPORTANT NOTE: The
communication port. The default listen cycle is 4. If set to zero, the symbol should be displayed
continuously. See the PCCU32 Help files for communication port setup to learn how this setting
effects power usage.
To set up and schedule the remote communication port for power conservation:
Select TF Remote – COM1 in the navigation tree.
Select the Schedule tab. Click Help to locate schedule parameter definitions.
Set required values and Click Send.
If RS-232 Modem was selected:
Select the Modem tab to set up modem parameters. Click Help to locate parameter
definitions.
Click Send after all values have been set.
6 6 | XSE RI ES G5 | 2 10 6 02 6MNAA
Serial port settings
Default
Parameter
15
Baud
40
Parity
420
Data bits
40
Stop bits
80
Units
symbol flashes according to the listen cycle defined for the
Default
9600
None
8
1
XFCG5 J11
XRC J7
1-2
1-2
2-3
2-3
Annunciators
A1
A7
A
L
D
C
Alarm
codes
L
A2
A8