ABB PSTX Series Installation And Commissioning Manual page 139

Hide thumbs Also See for PSTX Series:
Table of Contents

Advertisement

Parameter
Description
number
18
Protections list 6
18.01
User defined DI status
18.02
User defined trip time
18.03
User defined out
18.04
User defined op
18.05
Ground fault trip time
18.06
Ground fault out
18.07
Ground fault op
18.08
Too long curr lim trip time
18.09
Too long curr lim out
18.10
Too long curr lim op
18.11
Too long start trip time
18.12
Too long start out
18.13
Too long start op
18.14
Auto-restart max delay
18.15
Auto-restart time-out out
18.16
Auto-restart time-out op
19
Protections list 7
19.01
HMI failure out
19.02
HMI failure op
19.03
Fieldbus failure out
19.04
Fieldbus failure op
19.05
Ext IO failure trip time
19.06
Ext IO failure out
19.07
Ext IO failure op
20
Warnings list 1
20.01
EOL level
20.02
EOL out
20.03
EOL warning
20.04
Locked rotor level
20.05
Locked rotor init time
20.06
Locked rotor out
20.07
Locked rotor
20.08
Thyristor OL out
20.09
Thyristor OL
20.10
Locked rotor trip time
21
Warnings list 2
21.01
Curr underload level
21.02
Curr underload trip time
21.03
Curr underload delay time
21.04
Curr underload out
21.05
Curr underload
21.06
Pwr factor underload level
21.07
Pwr factor underload trip
time
21.08
Pwr factor underload delay
time
21.09
Pwr factor underload out
21.10
Pwr factor underload
21.11
Current imb level
21.12
Current imb out
21.13
Current imbalance
Setting range
Active low, Active high
0.0 ... 60.0 s
Eventgroup 0 ... 6
Off, Stop-Manual, Stop-Automatic, Indication
0.1 ... 1.0 s
Eventgroup 0 ... 6
Off, Stop-Manual, Stop-Automatic, Indication
1 ... 600 s
Eventgroup 0 ... 6
Off, Stop-Manual, Stop-Automatic,
Indication. Fast ramp
1.0 ... 500.0 s
Eventgroup 0 ... 6
Off, Stop-Manual, Stop-Automatic, Indication
2 ... 3600 s
Eventgroup 0 ... 6
Off, Stop-Manual, Stop-Automatic, Indication
Eventgroup 0 ... 6
Off, Stop-Manual, Stop-Automatic,
Indication, Switch of HMI control
Eventgroup 0 ... 6
Off, Stop-Manual, Stop-Automatic,
Indication, Switch to I/O control
300 ... 30000 ms
Eventgroup 0 ... 6
Off, Stop-Manual, Stop-Automatic, Indication
40.0 ... 99.0%
Eventgroup 0 ... 6
On / Off
0.2 ... 10.0 x I e
1.0 ... 30.0 s
Eventgroup 0 ... 6
On / Off
Eventgroup 0 ... 6
On / Off
0.1 ... 100.0 s
0.4 ... 1.0 x I e
0 ... 10 s
0 ... 30 s
Eventgroup 0 ... 6
On / Off
0.00 ... 1.00
0 ... 10 s
0 ... 30 s
Eventgroup 0 ... 6
On / Off
10 ... 80%
Eventgroup 0 ... 6
On / Off
1SFC132081M0201
Number of
Fieldbus
decimals
ID
0
251
1
252
0
90
0
253
1
73
0
75
0
74
0
254
0
255
0
256
1
0
0
0
0
0
0
100
0
257
0
97
0
258
0
259
0
99
0
260
1
181
0
123
0
182
1
261
1
262
0
125
0
263
0
124
0
122
1
-
1
264
0
265
0
266
0
126
0
267
2
268
0
269
0
270
0
127
0
271
0
102
0
103
0
101
| Installation and commissioning manual | Functions
Default value
Actual
setting
Active high
1.0 s
0000010
Off
0.5 s
0000010
Off
10 s
0000010
Off
500.0 s
0000010
Off
3600
0000010
Off
0000010
Stop-Manual
0000010
7
Stop-Manual
1000 ms
0000010
Stop-Manual
90.0%
0000100
Off
1.2 x I e
5.0 s
0000100
Off
0000100
Off
0.1 s
0.8 x I e
1 s
5 s
0000100
Off
0.70
1 s
5 s
0000100
Off
70%
0000100
Off
139