Informative Examples - Huawei EM770W At Command Interface Specification

Umts m2m
Hide thumbs Also See for EM770W:
Table of Contents

Advertisement

HUAWEI UMTS M2M Module V100R001
AT Command Interface Specification

13.12.4 Informative Examples

After executing the following commands consecutively, the results are as follows:
Command 1: AT%IPCGDCONT=?
Result 1:
%IPCGDCONT:(1-16),"IP",,,(0-1),(0-1)
%IPCGDCONT:(1-16),"PPP",,,(0-1),(0-1)
OK
Note: This command supports two kinds of packet switching protocols: "IP" and "PPP".
The TEST command lists the values of other parameters supportable by each
protocol.
Command 2: AT%IPCGDCONT?
Result 2:
%IPCGDCONT:1,"IP","vcol.com","",0,0
OK
Note: The MS stores 1 PDP setting environment currently. The <cid> of this setting
environment is 1.
Command 3: AT%IPCGDCONT=16,"PPP","abc.com","10.111.145.233",1,1
Result 3:
OK
Note: This command stores 1 new BDP setting environment in the MS. The <cid> is
16.
Command 4: AT%IPCGDCONT?
Result 4: %IPCGDCONT:1,"IP","vcol.com","",0,0
%IPCGDCONT:16,"PPP","abc.com","10.111.145.233",1,1
OK
Note: Now the MS has an additional PDP setting environment whose <cid> is 16.
Command 5: AT%IPCGDCONT=16
Result 5:
OK
Note: Clear the PDP setting environment whose <cid>=16
Issue 18 (2009-06-22)