(3) Setting the in-position function
The following table lists the data to be set, setting condition, and check timing.
Setting item
In-position
Pr.8
range
222
Setting
Default
range
value
1 to
5pulse
20479pulse
Setting condition
The data can be set anytime.
Note that the set data at the rise
(ON) of a start signal is used for
the operation. If the data is
written when BUSY signal
(X14) is on, the data will be
accepted at the rise (ON) of the
next start signal.
Buffer
Check timing of
memory
the set data
address
(decimal)
• When a positioning
start signal (Y21 to
Y23) is turned on
• When a JOG start
signal (Y24, Y25) is
turned on
• When OPR start
signal (Y20) is
turned on
24