Mitsubishi Electric MELSEC Q Series User Manual page 65

Positioning module
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

(5) Restoring the zero/gain adjustment value of the factory default
Writing "1" in "
Cd.12
adjustment value of the factory default. Once the restoration was completed, the QD73A1 sets "0" in
"
Factory default zero/gain adjustment value restoration request".
Cd.12
Once the restoration was completed, analog output voltage becomes 0V and the QD73A1 sets "1: Adjusting
zero" in "
Zero/gain adjustment status".
Md.10
Note that "
Factory default zero/gain adjustment value restoration request" is usable only in the zero/gain
Cd.12
adjustment mode.
Setting item
Factory default zero/gain
adjustment value restoration
Cd.12
request
Zero value and gain value of the factory default are set as below.
• Zero value: 0V
• Gain value: 10V
Note that the values above were set when "Accumulated pulse setting" was the default value (-14800 to 14800pulse).
Factory default zero/gain adjustment value restoration request" restores the zero/gain
Setting range
1: Restore the
zero/gain adjustment
value
CHAPTER 4 SETTINGS AND PROCEDURE BEFORE OPERATION
Default value
Execution condition
The module must be in
0
the zero/gain adjustment
mode.
4
Buffer memory
address
(decimal)
96
63