Table 7-6 Details Of Error Freeze Information Table - Hitachi S10mini User Manual

Option
Hide thumbs Also See for S10mini:
Table of Contents

Advertisement

7 TROUBLESHOOTING
When the FL.NET module detects a hardware error, it illuminates the LER lamp and saves error
freeze information. The FL.NET module operation comes to a stop.
When the module is installed in a different model from the model in which the parameters shown in
"5 USER GUIDE" were set, a parameter error occurs. Concretely, there are such 2 cases as
shown below.
Case 1: In the S10V, when the FL.NET module in which parameters were set is installed in the
S10mini, "FLNMROM3" or "FLNSROM3" is displayed on the indicator of the CPU
module.
Case 2: In the S10mini, when the FL.NET module in which parameters were set is installed in the
S10V, "0x010B" is displayed on the error log of the tool (S10V BASE SYSTEM).
The above function is intended to prevent a malfunction by referring to the parameters set in a
different model. If a checksum error occurs in the contents of parameter setup, this results in a
parameter error. When this parameter error occurs, open the Parameter setup screen of the
installed model and change the setup as required.
Main module Submodule
/D40400
/DC0400
/D40404
/DC0404
/D40410
/DC0410
/D40414
/DC0414
/D40418
/DC0418
/D4041C
/DC041C
/D40420
/DC0420
/D40424
/DC0424
/D40428
/DC0428
/D4042C
/DC042C
/D40430
/DC0430
/D40434
/DC0434
/D40438
/DC0438
/D4043C
/DC043C
/D40440
/DC0440
/D40444
/DC0444
/D40448
/DC0448
/D4044C
/DC044C
/D40450
/DC0450
/D404FC
/DC04FC
Note: Stack frame detailed descriptions are given on the next page.

Table 7-6 Details of Error Freeze Information Table

16
31
2
2
Error code
D0 register
D1 register
D2 register
D3 register
D4 register
D5 register
D6 register
D7 register
A0 register
A1 register
A2 register
A3 register
A4 register
A5 register
A6 register
A7 register
Stack frames
(4 words, 6 words, bus error)
0
15
2
2
0010H
0011H
0012H
0013H
0014H
0016H
0017H
0018H
0019H
001AH
0100H
0102H
0103H
0105H
010BH
0113H
0114H
7-10
Code
Error description
Bus error
Address error
Invalid instruction
Division by 0
Privilege violation
Format error
Spurious interrupt
Unused exception
(CHK, TRAPV, L1010, etc.)
Parity error
Power failure notice
Module number setting switch error
ROM1 checksum error
RAM1 compare error
RAM2 compare error
ROM3 checksum error
IP address not registered
MAC address error