(3) Main specifications for coaxial cable installation
Table 8-15 shows the main specifications for coaxial cable installation.
Cable laying
Cable clamping
Tension
Cable weight
(4) 10BASE5 coaxial cable
For the cable recommended for use with the FL.NET module, see "8.5.1 Ethernet component
list."
(5) Coaxial connector attachment
(a) Applicable connector
For the connector recommended for use with the FL.NET module, see "8.5.1 Ethernet
component list."
(b) Installation procedure
The procedure for attaching the coaxial connector (Type: HBN-N-PC) is shown below:
① Peeling off the PVC sheath
Figure 8-42 Peeling Off the Coaxial Cable Covering (PVC Sheath)
Table 8-15 Coaxial Cable Specifications
Item
100 mm or more in radius
100 mm or more in radius
245 N maximum
188 kg (per length of 1 km)
10 ± 1 0
Specifications
8-49
8 APPENDIXES