Using Imana 200 To Collect Information In Batches - Huawei E9000 Troubleshooting Manual

Hide thumbs Also See for E9000:
Table of Contents

Advertisement

Huawei Servers
Troubleshooting

8.2 Using iMana 200 to Collect Information in Batches

This method applies only to servers and blades. To collect logs of switch modules
in batches, use the MM910 WebUI.
Procedure
Step 1 Use PuTTY to log in to the server. For details, see
Over a Network Port by Using PuTTY
Passthrough Module, or Switch Module by Using the SOL Function of the
MM910.
Step 2 On the iMana 200 CLI, run the imtool command (for versions earlier than 7.01) or
the ipmcset -t maintenance -d imtool command (for 7.01 and later versions).
Information similar to the following is displayed:
root@BMC:/#ipmcset -t maintenance -d imtool
tar: removing leading '/' from member names
Tar result information success.
iMana:/->
If the following information is displayed, log collection is successful.
tar: removing leading '/' from member names
Tar result information success.
Step 3 Use a cross-platform file transfer tool to connect to the iMana 200 IP address.
In this document, WinSCP is used as the cross-platform file transfer tool. For
details, see
Step 4 Download the tar.gz package in the /tmp directory on iMana 200 to a directory on
the local PC. See
Figure 8-15 WinSCP window
Issue 20 (2020-09-25)
Figure 8-14 Product SN
8.19 Using WinSCP to Transfer
Figure
8-15.
Copyright © Huawei Technologies Co., Ltd.
8.15 Logging In to a Server
or
8.17 Logging In to a Compute Node,
Files.
8 Common Operations