Huawei E9000 Troubleshooting Manual page 74

Hide thumbs Also See for E9000:
Table of Contents

Advertisement

Huawei Servers
Troubleshooting
Indicator
Memory riser
backup indicator
Memory riser
mirroring
indicator
Compute module
status indicator
Issue 20 (2020-09-25)
Status
Blinking yellow
Off
Steady green
Off
Steady green
Off
Steady green
Blinking red (once
every second)
Blinking red (five
times every
second)
Off
Copyright © Huawei Technologies Co., Ltd.
5 Diagnosing and Rectifying Faults
Meaning
The memory riser
is waiting to
cancel the hot
swap operation.
To cancel the
operation, press
the memory riser
button again
within 5 seconds.
The hot insertion
or removal
operation is
normal.
The memory riser
is idle.
The memory riser
is not idle.
Memory mirroring
has been
configured on the
memory riser.
Memory mirroring
has not been
configured on the
memory riser.
The compute
module is
operating
properly.
The compute
module is faulty.
The compute
module is not
installed properly.
The compute
module is not
powered on.
Diagnosis
N/A
N/A
N/A
N/A
View the iBMC
event alarm logs
to check whether
the compute
module is faulty.
Check whether
the compute
module is
installed properly.
65