Huawei E9000 Troubleshooting Manual page 87

Hide thumbs Also See for E9000:
Table of Contents

Advertisement

Huawei Servers
Troubleshooting
Model
RH5885H V3
1288H V5, 1288X V5, 2288
V5, 2288C V5, 2288H V5,
2288X V5, 5288 V5, 5288X
V5
2298 V5
2488 V5, 2488H V5, 5885H
V5
XH321 V5, XH321L V5
XH628 V5
CH121 V5, CH242 V5,
CH121L V5, and CH221 V5
CH225 V5
Atlas 800 AI training server
(model 9010)
Issue 20 (2020-09-25)
Minimum
Configuration
Two CPUs in the CPU1
and CPU2 sockets
One DIMM in the DIMM
A1 slot of the first
memory board
One CPU in the CPU1
socket
One DIMM in the
DIMM000(A) slot
Two CPUs in the CPU1
and CPU2 sockets
One DIMM in the
DIMM000(A) slot
Two CPUs in the CPU1
and CPU2 sockets
One DIMM in the
DIMM000(A) slot
One CPU in the CPU1
socket
One DIMM in the
DIMM000(A) slot
One CPU in the CPU1
socket
One DIMM in the
DIMM000(A) slot
One CPU in the CPU1
socket
One DIMM in the
DIMM000 slot
Two CPUs in the CPU1
and CPU2 sockets
One DIMM in the
DIMM000(1A1) slot
Two CPUs in the CPU1
and CPU2 sockets
Copyright © Huawei Technologies Co., Ltd.
5 Diagnosing and Rectifying Faults
Remarks
One PSU in any slot
One PSU in any slot
One PSU in any slot
None
None
The RAID controller
card is mounted to
CPU 2. If the OS drive
is connected to the
RAID controller card,
the OS cannot be
accessed.
None
None
None
78