Huawei E9000 Troubleshooting Manual page 98

Hide thumbs Also See for E9000:
Table of Contents

Advertisement

Huawei Servers
Troubleshooting
Fault
Symptom
The server
repeatedl
y powers
on and
then
powers
off.
Issue 20 (2020-09-25)
Handling Procedure
1. Enable the video recording
function on the iMana 200 or
iBMC WebUI.
2. Set the printing level for
debugging the BIOS with the
iMana 200 or iBMC CLI, restart
the server, and save system
serial port logs. When the fault
is repeated, collect iMana 200
or iBMC logs and download
the .bin file of the BIOS.
NOTE
You can run the ipmcset -t
maintenance -d biosprint -v 1
command to print all BIOS logs.
For details, see "Querying and
Setting BIOS Print Enablement
Status (biosprint)" in the
User Guide
of the required
version.
3. Restore the default BIOS
settings, and check whether
the server operates properly.
● If yes, modify the BIOS
parameters in the OS side
based on actual
requirements.
● If no, collect iMana 200 or
iBMC logs, download
the .bin file of the BIOS. For
details, see the
Guide
of the corresponding
version.
NOTE
For an E9000 server, you are advised
to use the MM910 for one-click log
collection.
Copyright © Huawei Technologies Co., Ltd.
5 Diagnosing and Rectifying Faults
Quick Recovery Method
● If yes, no further action is
● If no, go to 4.
4. Retain only the minimum
server configuration (a
single CPU, a single
mainboard, and a single
DIMM). Then check whether
the fault is rectified.
● If yes, no further action is
● If no, go to 5.
5. Check whether the CPUs,
mainboard, and memory
modules are faulty, and
replace the faulty
iBMC
components.
iBMC User
required.
required.
89