Troubleshooting
Table 5-16 E9000 switch module indicators
Indicator
Stack status
indicator (STAT)
Health indicator
(HLY)
Issue 20 (2020-09-25)
Status
Steady green
Blinking green
Off
Steady green
Blinking red
Off
Copyright © Huawei Technologies Co., Ltd.
5 Diagnosing and Rectifying Faults
Meaning
A switch module
that can be
stacked is active
in stacking mode
or is not stacked,
and is operating
properly.
A switch module
that cannot be
stacked is
operating
properly.
A switch module
that can be
stacked is standby
or slave in
stacking mode
and is operating
properly.
A switch module
that cannot be
stacked is being
powered on.
The switch
module is not
powered on.
The switch
module is
operating
properly.
The switch
module has a
fault alarm or is
not installed
properly.
The switch
module is not
powered on.
Diagnosis
Procedure
N/A
N/A
Log in to the
HMM WebUI to
view event
alarms, and check
whether the
switch module is
installed and
operating
properly.
N/A