ACH580 Ultra-Low Harmonic Drives Installation, Operation and Maintenance Manual
Code
(hex)
5693
5696
5697
5698
6181
6306
6481
6487
64A1
64A4
64A6
Fault / Aux. code
Measurement circuit DFF
PU state feedback
Charging feedback
Unknown PU fault
FPGA version
incompatible
FBA A mapping file
Task overload
Stack overflow
Internal file load
Rating ID fault
Adaptive program
000A
000C
000E
0011
0012
Cause
Measurement circuit
Contact your local ABB
fault.
representative.
State feedback from
Contact your local ABB
output phases does not
representative.
match control signals.
Charging feedback
Check the feedback signal coming
signal missing.
from the charging system
The power unit logic
Check the logic and software
has generated a fault
compatibility.
which is not known by
the software.
Firmware and FPGA
Reboot the control unit (using
versions are
parameter 96.08 Control board boot)
incompatible.
or by cycling power. If the problem
persists, contact your local ABB
representative
Fieldbus adapter A
Contact your local ABB
mapping file read error.
representative.
Internal fault.
Reboot the control unit (using
parameter 96.08 Control board boot)
or by cycling power. If the problem
persists, contact your local ABB
representative
Internal fault.
Reboot the control unit (using
parameter 96.08 Control board boot)
or by cycling power. If the problem
persists, contact your local ABB
representative
File read error.
Reboot the control unit (using
parameter 96.08 Control board boot)
or by cycling power. If the problem
persists, contact your local ABB
representative
Rating ID load error.
Contact your local ABB
representative.
Error running the
Check the auxiliary code (format
adaptive program.
XXYY ZZZZ).
"XX" specifies the number of the state
(00=base program) and "YY" specifies
the number of the function block
(0000=generic error).
"ZZZZ" indicates the problem.
Program corrupted or
Restore the template program or
block non-existent
download the program to the drive.
Required block input
Check the inputs of the block.
missing
Program corrupted or
Restore the template program or
block non-existent
download the program to the drive.
Program too large.
Remove blocks until the error stops.
Program is empty.
Correct the program and download it
to the drive.
ACH580 Ultra-Low Harmonic Drives Installation
65
What to do

Advertisement

loading