Replacing the auxiliary cooling fan, frame R6
occur.
1. Stop the drive and disconnect it from the power line. Wait for 5 minutes and then
make sure by measuring that there is no voltage. See section
electrical work
2. Remove the upper front covers. See section
3. Release the retaining clips.
4. Lift the fan off.
5. Unplug fan power supply wires.
6. Remove the grille from the fan.
7. Install the new fan in reverse order.
8. Note: Make sure that the arrow on the fan points up.
9. Reinstall the front covers. See section