Siemens SINUMERIK 840D sl Programming Manual page 403

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Deactivate travel to fixed stop: FXS[<axis>] = 0
Deselection of the function triggers a preprocessing stop.
The block with FXS[<axis>]=0 may and should contain traversing movements.
Example:
Program code
X200 Y400 G01 G94 F2000 FXS[X1]=0
...
CAUTION
The traversing movement to the retraction position must move away from the fixed stop,
otherwise damage to the stop or to the machine may result.
The block change takes place when the retraction position has been reached. If no retraction
position is specified, the block change takes place immediately the torque limit has been
deactivated.
Clamping torque (FXST) and monitoring window (FXSW)
Any programmed torque limiting FXST is effective from the block start, i.e. the fixed stop is
also approached at a reduced torque. FXST and FXSW can be programmed and changed in
the part program at any time. The changes take effect before traversing movements in the
same block.
Programming of a new fixed stop monitoring window causes a change not only in the window
width, but also in the reference point for the center of the window if the axis has moved prior
to reprogramming. The actual position of the machine axis when the window is changed is the
new window center point.
CAUTION
The window must be selected such that only a breakaway from the fixed stop causes the
fixed stop monitoring to respond.
Further information
Rise ramp
A rate of rise ramp for the new torque limit can be defined in MD to prevent any abrupt
changes to the torque limit setting (e.g. insertion of a quill).
Alarm suppression
The fixed stop alarm can be suppressed for applications by the part program by masking the
alarm in a machine data item and activating the new MD setting with NEW_CONF.
Fundamentals
Programming Manual, 09/2011, 6FC5398-1BP40-2BA0
Supplementary commands
14.6 Travel to fixed stop (FXS, FXST, FXSW)
Comment
; Axis X1 is retracted from the fixed stop
to position X = 200 mm. All other
parameters are optional.
403

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828dSinumerik 840de sl

Table of Contents