I/O Signals Comparison To Cpu Module - Mitsubishi Electric MELSEC-A/QnA Series Handbook

Table of Contents

Advertisement

7
POSITIONING MODULE REPLACEMENT

7.6.3 I/O signals comparison to CPU module

An addition or change of a sequence program is required because the I/O signals partly differ between
the modules.
For details of the I/O signals or sequence program, refer to the MELSEC-Q QD73A1 Positioning Module
User's Manual.
Input (X)
Signal name
Unused
(The first half slot is Empty 16 points.)
WDT error, H/W error
Module READY
OPR request
OPR complete
BUSY
Positioning complete
In-position
Excessive error
Error detection
Overflow
Underflow
Servo READY
Near-point dog
External stop
Upper limit signal
Lower limit signal
OPR start complete
Absolute positioning start complete
Forward start complete
(for the incremental positioning and the
speed-position control switching)
Reverse start complete
(for the incremental positioning and the
speed-position control switching)
Synchronization flag
Zero/gain adjustment data writing complete
flag
Zero/gain adjustment change complete flag
Set value change complete flag
Operating status of the speed-position
control switch mode
*2
Use prohibited
*1
The XY number same as the AD70 can be used for the QD73A1 by setting "Empty 0 point" to the "Unused" area of the
QD73A1 (first half slot: Empty 16 points) in I/O assignment of PLC parameter.
*2
A "Use prohibited" area is reserved for the system use and cannot be used by a user.
If it is turned on/off through a sequence program, the normal operation of the module cannot be guaranteed.
7
- 49
AD70
QD73A1
X00
--
to
*1
X0F
X00
X10
X01
X11
X02
X12
X03
X13
X04
X14
X05
X15
X06
X16
X07
X17
X08
X18
X09
X19
X0A
X1A
X0B
X1B
X0C
X1C
X0D
X1D
X0E
X1E
X0F
X1F
--
X20
--
X21
--
X22
--
X23
--
X24
--
X2A
--
X2B
--
X2C
--
X2D
X25 to X29
X10
to
X2E, X2F
X1F
Output (Y)
Signal name
Unused
(The first half slot is Empty 16 points.)
Zero/gain adjustment data writing request
Zero/gain adjustment change request
Set value change request
OPR start
Absolute positioning start
Forward start
Reverse start
Forward JOG start
Reverse JOG start
Speed-position mode restart
Stop
Error reset
Overflow reset
Underflow reset
Speed-position switching enable
PLC READY
*2
Use prohibited
AD70
QD73A1
Y00
--
to
*1
Y0F
--
Y1A
--
Y1B
--
Y1C
Y10
Y20
Y11
Y21
Y12
Y22
Y13
Y23
Y14
Y24
Y15
Y25
Y16
Y26
Y17
Y27
Y18
Y28
Y19
Y29
Y1A
Y2A
Y1C
Y2C
Y1D
Y2D
Y00
Y10
to
to
Y0F
Y19
Y1D
Y1B
to
Y1E, Y1F
Y1F
--
Y2E, Y2F