Outdoor un t nstallat on
Before perform ng electr cal work, read these regulat ons
1. All w r ng must comply w th local and nat onal electr cal codes, and must be nstalled
by a l censed electr c an.
2. All electr cal connect ons must be made accord ng to the Electr cal Connect on
D agram located on the s de panels of the ndoor and outdoor un ts.
3. If there s a ser ous safety ssue w th the power supply, stop work mmed ately.
Expla n your reason ng to the cl ent, and refuse to nstall the un t unt l the safety
ssue s properly resolved.
4. Power voltage should be w th n 90-100% of rated voltage. Insuff c ent power
supply can cause electr cal shock or f re.
5. If connect ng power to f xed w r ng, nstall a surge protector and ma n power sw tch
w th a capac ty of 1.5 t mes the max mum current of the un t.
A
6. If connect ng power to f xed w r ng, a sw tch or c rcu t breaker that d sconnects all
poles and has a contact separat on of at least 1/8 n (3mm) must be ncorporated n
the f xed w r ng. The qual f ed techn c an must use an approved c rcu t breaker or
sw tch.
7. Only connect the un t to an nd v dual branch c rcu t outlet. Do not connect another
appl ance to that outlet.
8. Make sure to properly ground the a r cond t oner.
9. Every w re must be f rmly connected. Loose w r ng can cause the term nal to
overheat, result ng n product malfunct on and poss ble f re.
10. Do not let w res touch or rest aga nst refr gerant tub ng, the compressor, or any
mov ng parts w th n the un t.
11. If the un t has an aux l ary electr c heater, t must be nstalled at least 1 meter (40 n)
away from any combust ble mater als.
Warn ng
A
Before perform ng any electr cal or w r ng work, turn off
the ma n power to the system.
1. Prepare the cable for connect on:
Use the r ght cable
Indoor Power Cable ( f appl cable): H05VV-F or H05V2V2-F
Outdoor Power Cable: H07RN-F
S gnal Cable: H07RN-F
34 / 120 EN
Spl t-type room a r cond t oner / Installat on Manual