8
A r evacuat on
Connect ve p pe
A r purg ng
length (m)
method
≤ Standard p pe
Vacuum
length
Pump
> Standard p pe
Vacuum
length
Pump
Warn ng
A
DO NOT m x refr gerant types.
Spl t-type room a r cond t oner / Installat on Manual
Add t onal refr gerant per p pe length
L qu d S de: Ø 6.35 (ø 0.25")
R22:
(P pe length – standard length) x 30g/m
(P pe length – standard length) x 0.32oZ/ft
Inverter R410A:
(P pe length – standard length) x 15g/m
(P pe length – standard length) x 0.16oZ/ft
F xed-frequency R410A:
(P pe length – standard length) x 20g/m
(P pe length – standard length) x 0.21oZ/ft
Add t onal refr gerant
N/A
L qu d S de: Ø 9.52 (ø 0.375")
(P pe length – standard length) x 60g/m
(P pe length – standard length) x 0.64oZ/ft
Inverter R410A:
(P pe length – standard length) x 30g/m
(P pe length – standard length) x 0.32oZ/ft
F xed-frequency R410A:
(P pe length – standard length) x 40g/m
(P pe length – standard length) x 0.42oZ/ft
R22:
47 / 120 EN