Available languages

7
Refr gerant p p ng connect on
Flare form
A
P pe
F g. 7.5
6. Place flar ng tool onto the form.
7. Turn the handle of the flar ng tool clockw se unt l the p pe s fully flared.
8. Remove the flar ng tool and flare form, then nspect the end of the p pe for cracks and even flar ng.
Step 4: Connect p pes
When connect ng refr gerant p pes, be careful not to use excess ve torque or to deform the p p ng n
any way. You should f rst connect the low-pressure p pe, then the h gh-pressure p pe.
M n mum bend rad us
When bend ng connect ve refr gerant p p ng, the m n mum bend ng rad us s 10cm. See F g. 7.6
10cm (4 n)
Rad us
F g. 7.6
40 / 120 EN
Spl t-type room a r cond t oner / Installat on Manual