Chapter 2 Configuring and Upgrading the System
3.
Run team creation script(ftSysLbfo.ps1).
Information on the network adapter is displayed.
>.\ftSysLbfo.ps1
Express5800/R310g-E4, R320g-E4, R320g-M4 Maintenance Guide (Windows)
Important
If run the team creation script immediately after starting the system, the following
message may be output.
'Make sure ftSysMad.exe is running and try again.'
Team creation script(ftSysLbfo.ps1) gets information from ftSys Maintenance and
Diagnostics(MAD) service, but the service can not respond to the information
request for about 10 minutes immediately after system startup, so the above
message will be displayed.
If this message is displayed, make sure duplex status in the ftServer utility and run
the script again.
[How to Check]
In ftServer Utility, Open [ft Server] - [CPU Module] - [CPU Module(ID:0)] in the tree
pane on the left side of the window.
Wait until other than "Unknown" is displayed in status.
If [CPU Module(ID:0)] does not appear under [CPU Module], restart ftServer utility.
If displayed 'Unknown' in status, press F5 to refresh.
[In addition]
If 'ftSys Maintenance and Diagnostics(MAD)' service is stopped due to some kind of
trouble, the status display of ft server utility will remain 'Unknown' even if the above
[How to Check] is executed. In that case, check the status of 'ftSys Maintenance and
Diagnostics(MAD)' on the 'Service' list.
If the service is in a stopped state, start it, wait about two minutes, and then carry
out [How to Check] again.
3. Duplex LAN Configuration
139