Huawei SmartDC V100R021C10 User Manual page 213

Data center controller
Hide thumbs Also See for SmartDC V100R021C10:
Table of Contents

Advertisement

ECC800 Data Center Controller
User Manual
In the URL,
Step 3 Log in to the OMU portal. Set the service system and operating system passwords
at the first login.
1.
2.
3.
4.
Step 4 Configure disk initialization.
1.
2.
3.
Issue 04 (2021-10-09)
IP address indicates the IP address of the IVS1800.
NO TE
The OMU portal supports Internet Explorer 10.0 and later versions.
Set the password for user admin of the service system.
Set the password for user admin of the operating system.
Set the password for user root of the operating system.
Use the configured service system password to log in to the OMU portal
again.
NO TE
Recording data can be stored only after you install and initialize the disks.
Choose Local Configuration > Local Disk.
In the upper right corner of the RAID Groups area, click Initial Disk
Configure disk initialization.
Figure 6-62 Disk initialization (RAID 5 economical configuration by default)
Table 6-35 RAID mode description
Parameter Name
RAID High Reliability
Copyright © Huawei Technologies Co., Ltd.
6 Feature Description
Description
– RAID5 RecommendedFour or
more hard disks are required, and
one hard disk is used as the hot
spare disk.
– RAID5 Economical
Three or more hard disks are
required, and one hard disk is
used as the hot spare disk.