On-Screen Message Descriptions; Fault Messages - Hitachi IJ RX2-SD160 Instruction Manual

Ink jet printer for industrial marking
Table of Contents

Advertisement

9.2 On-screen message descriptions

9.2.1 Fault messages

(1) Faults that invoke ink stoppage
No.
Message
1
Ink Low Fault
Main Ink Tank Too
2
Full
Deflection Voltage
3
Fault
Ink replenishment
4
Time-out
Ink Drop Charge
5
Too Low
System operation
6
error C
System operation
7
error M
System operation
8
error S
Deflection Voltage
9
Leakage
Makeup
10
replenishment
Time-out
11 Makeup Low Fault
Ink Heating Unit
12
Temprature Too
High
Multi DC Power
13
Supply Fan Fault
Meaning of message
The ink reservoir is almost empty and
printing will stop.
(If the ink is not added or replaced within
60 minutes after warning output, the printer
comes to a stop with the warning condition
replaced by a fault condition.)
The ink level in the main ink tank is too
high.
The high-voltage power supply output
voltage is too low or too high.
The automatic ink refill process exceeded
the time limit.
The ink drops are poorly charged.
Unexpected error occurred.
Unexpected error occurred.
Unexpected error occurred.
The deflection electrode voltage is too low.
The automatic makeup refill process
exceeded the time limit.
The makeup reservoir is almost empty and
printing will stop.
(if replenishment is not effected within 60
minutes after warning output)
The temperature of the ink heater in the
print head is too high.
The heater will be temporarily deactivated.
The cooling fan in the multi DC power
supply has a fault. The ink ejection will
stop and the printer will be automatically
shutdown.
Remedy
● Add ink to the ink reservoir.
(
8.1).
● Drain proper amount of ink
in the main ink tank.
(
Technical manual
6.3, 6.13).
● Contact your nearest local
distributor.
● Contact your nearest local
distributor.
● Clean the gutter, deflection
electrode, and its
surroundings.
● Adjust the excitation setting
to make sure that the ink
drops are well made.
(
Technical manual 6.11).
● Adjust ink pressure.
(
Technical manual 6.10).
● Turn the power OFF and then
back ON after 10 seconds.
● Turn the power OFF and then
back ON after 10 seconds.
● Turn the power OFF and then
back ON after 10 seconds.
● Clean and dry the deflection
electrode and nearby parts.
● Contact your nearest local
distributor.
● Add the makeup to the
makeup reservoir.
(
8.2).
● Contact your nearest local
distributor.
● Contact your nearest local
distributor.
●On-screen message descriptions 9-3