3. SIGNALS AND WIRING
3.9 Servo motor with electromagnetic brake
CAUTION
www.DataSheet4U.com
Note the following when the servo motor equipped with electromagnetic brake is used for applications
requiring a brake to hold the motor shaft (vertical lift applications):
1) Set "
Note that this will make the zero speed signal (ZSP) unavailable.
2) Do not share the 24VDC interface power supply between the interface and electromagnetic
brake. Always use the power supply designed exclusively for the electromagnetic brake.
3) The brake will operate when the power (24VDC) switches off.
4) While the reset signal is on, the base circuit is shut off. When using the servo motor with a
vertical shaft, use the electromagnetic brake interlock signal (MBR).
5) Switch off the servo-on signal after the servo motor has stopped.
(1) Connection diagram
Servo amplifier
VIN
MBR
SG
(2) Setting
1) Set "
2) Using parameter No. 33 (electromagnetic brake sequence output), set a time delay (Tb) at servo-off
from electromagnetic brake operation to base circuit shut-off as in the timing chart shown in (3) in
this section.
Configure the electromagnetic brake operation circuit so that it is activated not only
by the servo amplifier signals but also by an external emergency stop signal.
Contacts must be open when
servo-on signal is off or when an
alarm (trouble) is present and when
an electromagnetic brake signal.
The electromagnetic brake is provided for holding purpose and must not be used
for ordinary braking.
POINT
Refer to the Servo Motor Instruction Manual for specifications such as the
power supply capacity and operation delay time of the electromagnetic
brake.
1 " in parameter No.1 to make the electromagnetic brake interlock signal (MBR) valid.
External
power
RA
supply
24VDC
External power
supply 24VDC
1 " in parameter No.1 to make the electromagnetic brake interlock signal (MBR) valid.
Servo motor
RA
Electromagnetic brake
Emergency
stop
RA
B1
B2
3 - 41
Circuit must be
opened during
emergency stop signal.
EMG
24VDC
Servo motor