Siemens SIMATIC S7-1500 System Manual page 95

Drive controller
Hide thumbs Also See for SIMATIC S7-1500:
Table of Contents

Advertisement

Danger to life due to unsuitable firmware version
Operation of the SINAMICS S220 Booksize component with an unsuitable firmware version
can lead to unsafe operational states, for example, overheating of converter components,
unexpected acceleration of a motor or malfunctioning of the safety functions.
Use firmware V5.2 SP3 HF10 or later.
Use of "older" DRIVE-CLiQ components
Some "older" DRIVE-CLiQ components cannot be used with the SIMATIC Drive Controller or
with SINAMICS S120 CU320-2.
Table 5- 9
DRIVE-CLiQ components that cannot be used with SIMATIC Drive Controller and SINAMICS S120 CU320-2
DRIVE-CLiQ components
Single Motor Modules (SMM)
Double Motor Modules (DMM)
Line Modules (ALM/SLM)
Chassis power units
(Line Modules, Motor Modules, Power Modules)
Sensor Modules Cabinet SMC30
Terminal Modules TM31/TM41
Sensor Module External SME20/25
Control Unit Adapter CUA31
If you use invalid components, then a topology error is reported, F01360 Topology: Actual
topology invalid.
Additional information
You can find a description of the CPU and SINAMICS Integrated functions that require a
license in the section Runtime licensing (Page 278).
You can find a detailed description of the functions of SINAMICS S120 CU320-2 in the
SINAMICS S120 Drive Functions
(https://support.industry.siemens.com/cs/us/en/view/109781535) function manual.
SIMATIC Drive Controller
System Manual, 11/2023, A5E46600094-AD
WARNING
Notes
6SL31*
(all Motor Modules Booksize Compact 6SL34*
can be used)
6SL313*
can generally be used:
-
-
-
-
All BLMs (6SL313*)
SLM (6SL313*) 5 and 10 kW
Line Modules: 6SL333*
Motor Modules: 6SL332*
Power Modules: 6SL331*
System overview
5.3 SIMATIC Drive Controller functions
Ending of the article
no.
< 3
< 3
< 3
< 2
< 1
< 3
< 1
93

Advertisement

Table of Contents
loading