Dispenser cabinet error codes
Description
FRONTEND_DOOR
OUTPUT_FUSE_PLUS_BLOWN
OUTPUT_FUSE_MINUS_BLOWN
OUTPUT_CONTACTOR_PLUS_Closing_Timeout
OUTPUT_CONTACTOR_PLUS_Opening_Timeout
OUTPUT_CONTACTOR_MINUS_Closing_Timeout
OUTPUT_CONTACTOR_MINUS_Opening_Timeout
CHARGING_SYSTEM_INCOMPATIBILITY
EV_SHIFT_POSITION
CHARGING_VOLTAGE_OUT_OF_RANGE
EVRESS_MALFUNCTION
RESS_TEMPERATURE_INHIBIT
CHARGING_CURRENT_DIFF
CHARGER_CONNECTOR_LOCK_FAULT
Communication to Server Lost
CAN_COMMUNICATION_LOST
CB12_BREAKER_TRIPPED
CB13_BREAKER_TRIPPED
CB14_BREAKER_TRIPPED
Table 9-2: Dispenser error codes
102
Error Number
Error Handling
201
Close the cabinet door completely
Check wiring from SF20 to A1_PLC
Check mounting of the door switch for proper function
202
Check F15 for a blown fuse
Ensure that the low voltage microswitch is making
contact for each fuse
203
Check F16 for a blown fuse
Ensure that the low voltage microswitch is making
contact for each fuse
204
Check for damage on K16 contactor coil
Check for a broken wire or a loose connection
205
Check the K15 contactor for damage
206
Check for damage on K16 contactor coil
Check for a broken wire or a loose connection
207
Check the K15 contactor for damage
208
Vehicle-generated alarm. Refer to vehicle OEM manual
for troubleshooting
209
Vehicle-generated alarm. Refer to vehicle OEM manual
for troubleshooting
210
Vehicle-generated alarm. Refer to vehicle OEM manual
for troubleshooting
211
Vehicle-generated alarm. Refer to vehicle OEM manual
for troubleshooting
212
Vehicle-generated alarm. Refer to vehicle OEM manual
for troubleshooting
213
Vehicle-generated alarm. Refer to vehicle OEM manual
for troubleshooting
214
Vehicle-generated alarm. Refer to vehicle OEM manual
for troubleshooting
215
Communication between main cabinet and dispenser
was interrupted. Check the network cables for loose
connections
Verify the main cabinet A31-PLC is in RUN state (Green
RUN/STOP LED)
216
Termination of CAN communication can be caused by
various specific events
Repeat the charging process
Check whether the fault persists
Check the CAN connections on the AKKA controller
217
Check feedback wire between PLC and CB12 for a
broken wire or a loose connection
Turn CB12 off and on
Check PS1 power supply for damage
218
Check feedback wire between PLC and CB13 for a
broken wire or a loose connection
Turn CB13 off and on
Check PS2 power supply for damage
219
Check feedback wire between PLC and CB14 for a
broken wire or a loose connection
Turn CB14 off and on
Check PS3 power supply for damage
OCPP Error Category
InternalError
OverCurrentFailure
OverCurrentFailure
PowerSwitchFailure
PowerSwitchFailure
PowerSwitchFailure
PowerSwitchFailure
EVCommunicationError
EVCommunicationError
EVCommunicationError
EVCommunicationError
EVCommunicationError
EVCommunicationError
EVCommunicationError
InternalError
InternalError
OverCurrentFailure
OverCurrentFailure
OverCurrentFailure

Advertisement