Alarm Messages In The Alarm History - Siemens SICHARGE UC 150 UL Installation And Operation Manual

Plug-in dispenser
Table of Contents

Advertisement

Canceling the alarm state
To cancel the alarm state, you need to disconnect the electric vehicle. When you unplug the charging
plug, the SICHARGE UC dispenser changes back to normal operation. When the display of the SICHARGE
UC dispenser shows the "Start" menu, the SICHARGE UC dispenser is ready for operation again.

9.5 Alarm messages in the alarm history

In case of an error, the SICHARGE UC dispenser triggers an alarm and automatically performs diagnostics.
For each alarm, the SICHARGE UC dispenser shows the following data in the "Alarm History" menu:
• Alarm time
• Date when the alarm was triggered
• Alarm status
• Alarm message
Alarm messages and error handling
In the "Alarm History" menu, the charging station lists the following alarm messages (error handling steps that involve
measuring or applying changes while SICHARGE UC is active should be performed by a local Siemens service representative):
Main cabinet error codes
Description
No_Error
Emergency Stop Active
Surge Arrester ON
A22-1-Ground Fault Relay Warning
A22-1-Ground Fault Relay Shutdown
High Input Voltage Warning
High Input Voltage Shutdown
Low Input Voltage Warning
Installation and Operations Manual | SICHARGE UC 150 UL Plug-in Dispenser
Error
Error
Code
Handling
0
N/A
1
Check the EMERGENCY STOP button
Eliminate the hazardous situation
Reset the EMERGENCY OFF button
Switch off the alarm
2
Check the surge protector SPD1 for a broken wire or a loose con-
nection
3
There may be a ground fault at the charging station or on the
vehicle
Ensure the CCS charging plug is in good condition
Insert the charging plug into the plug holder
Start the charging station in manual mode
If no fault appears, the vehicle is causing the ground fault
4
There may be a ground fault at the charging station or on the
vehicle
Ensure the CCS charging plug is in good condition
Insert the charging plug into the plug holder
Start the charging station in manual mode
If no fault appears, the vehicle is causing the ground fault
5
The voltage difference between the phases must not exceed a
tolerance range. The high output voltage can be caused by various
specific events
Repeat the charging process
Check whether the fault persists
6
Measure the level of the input voltage at the AC input breaker
Measure the AC input voltage on the SinePower board
Measure the artifical netural on the SinePower board
Measure the resistance of RY1 and RY2
7
Measure the level of the input voltage at the AC input breaker
Measure the AC input voltage on the SinePower board
Measure the artifical netural on the SinePower board
Measure the resistance of RY1 and RY2
OCPP Error
Category
NoError
OtherError
InternalError
GroundFailure
GroundFailure
Overvoltage
Overvoltage
Undervoltage