Plug-in dispenser
Table of Contents

Advertisement

SICHARGE UC 150 UL Plug-in Dispenser | Installation and Operations Manual
Selection criteria for a safe location
Select the location of the SICHARGE UC dispenser so that all charging actions are safe.
The user must be able to connect the vehicle without the use of extension cables. Therefore, the
SICHARGE UC dispenser must be within close proximity of the supplied mounting surfaces. The
SICHARGE UC dispenser must not pose a risk to persons or vehicles and must not be installed in
direct sunlight or on dark asphalt so as to preserve derating characteristics.
Properties of the mounting surface
• Floor mounting:
To ensure the stability of the SICHARGE UC dispenser, the floor space must meet the following requirements:
– Level
– Dry
– Sufficiently strong and able to bear the weight the dispenser
Note
Sealing the mounting plate
Seal the mounting plate and the cable openings in the foundation with suitable materials to prevent
moisture, animals and insects from getting inside the station.
• Wall mounting:
To ensure a secure hold of the SICHARGE UC dispenser, the mounting surface must meet
the following requirements:
– Level
– Dry
– Sufficiently solid and stable
– Take into account the static of building
You can find the dimensions for assembly in the section Preparing the mounting surface
Additional data can be found in the section Technical specifications
34
(Page
39).
(Page
114).