Siemens SICHARGE UC 150 UL Installation And Operation Manual page 98

Plug-in dispenser
Table of Contents

Advertisement

SICHARGE UC 150 UL Plug-in Dispenser | Installation and Operations Manual
Description
Q5-Primary Heater Trafo CB Opened
CB1-Secondary Control Trafo CB Opened
CB2-24V Digital Control PS Input CB Opened
CB3-24V Analog Control PS Input CB Opened
CB4-24V Output Contactor PS Input CB Opened
CB21-Sceondary Peripheral Trafo CB Opened
CB5-Bridge Rectifier Heatsink Fan CB Opened
CB6-IGBT Heatsink 1 Fan CB Opened
CB7-IGBT Heatsink 2 Fan CB Opened
CB8-Output Diode heatsink Fan CB Opened
High Cabinet Temperature Derating
High Cabinet Temperature Shutdown
Low Cabinet Temperature Derating
Low Cabinet Temperature Shutdown
CAN Communication Lost
Discharge Failed
Cable Check Failed
98
Error
Error
Code
Handling
55
Check feedback wire between PLC and Q5 for a broken wire or a
loose connection
Check Q5 for damage
56
Check feedback wire between PLC and CB1 for a broken wire or a
loose connection
Turn CB1 off and on
57
Check feedback wire between PLC and CB2 for a broken wire or a
loose connection
Turn CB2 off and on
58
Check feedback wire between PLC and CB3 for a broken wire or a
loose connection
Turn CB3 off and on
59
Check feedback wire between PLC and CB4 for a broken wire or a
loose connection
Turn CB4 off and on
60
Check feedback wire between PLC and CB21 for a broken wire or a
loose connection
Turn CB21 off and on
61
Check feedback wire between PLC and CB5 for a broken wire or a
loose connection
Turn CB5 off and on
62
Check feedback wire between PLC and CB6 for a broken wire or a
loose connection
Turn CB6 off and on
63
Check feedback wire between PLC and CB7 for a broken wire or a
loose connection
Turn CB7 off and on
64
Check feedback wire between PLC and CB8 for a broken wire or a
loose connection
Turn CB8 off and on
65
Check the air filter for dirt
66
Check the air filter for dirt
67
Ensure that the ambient temperature is not below -25 Celsius
Ensure that the heaters are operational
68
Ensure that the ambient temperature is not below -25 Celsius
Ensure that the heaters are operational
69
Termination of CAN communication can be caused by various
specific events
Repeat the charging process
Check whether the fault persists
Check whether the control of the power converter is
switched on and the LEDs are flashing
Check the CAN connections on the SinePower board and the AKKA
controller
71
Check F13 for a blown fuse
Check R13 for damage
Check K13 for damage
Ensure that K13 is opening and closing at the appropriate time
72
Check that the IGBTs are properly switching
Check the rectifiers for damage
Check for a balanced DC link voltages
OCPP Error
Category
OverCurrentFailure
OverCurrentFailure
OverCurrentFailure
OverCurrentFailure
OverCurrentFailure
OverCurrentFailure
OverCurrentFailure
OverCurrentFailure
OverCurrentFailure
OverCurrentFailure
HighTemperature
HighTemperature
OtherError
OtherError
InternalError
InternalError
InternalError

Advertisement

Table of Contents
loading

Table of Contents