Deactivate alarm and start charging again
To restart the charging process after an alarm, proceed as follows:
1. Press the "Warning / Fault Acknowledgment" button.
2. Press the main "Menu" button.
The SICHARGE UC dispenser deactivates the alarm. In the "Status" column, the status value "(I)O" is
displayed for the deactivated alarm. The SICHARGE UC dispenser continues the interrupted charging
process.
Note
Alarm that cannot be deactivated
When the SICHARGE UC dispenser does not deactivate the alarm after pressing the "Warning / Fault
Acknowledgment" button, the cause of the alarm is still present.
• Continue to observe the safety instructions in the general section Safety instructions
safety instructions for the operation
• Then check again whether you can eliminate the cause of the alarm.
• If you cannot eliminate the cause of the alarm, contact technical support.

8.7.4 Displaying information about the SICHARGE UC dispenser

In the "Charger Session Info" menu, the SICHARGE UC dispenser displays the actual voltage and
current values of the power supply.
Requirements
• You have opened the "Options" menu.
• You have pressed the "Charger Info" button in the "Options" menu.
"Charger Session Info" menu
In the "Charger Session Info" menu, the SICHARGE UC dispenser displays the following values of the
SICHARGE UC charging station: