Mounting the SICHARGE UC dispenser
To position the SICHARGE UC dispenser on the base area, follow these steps:
1. Position the SICHARGE UC dispenser on the mounting surface using the bolt anchors.
2. Guide any underground cables into the mounting base of the SICHARGE UC dispenser.
3. Check whether the alignment of the SICHARGE UC dispenser with the bolt anchors of the mounting surface is correct.
4. Lower the SICHARGE UC dispenser onto the base area.
5. Place the washers on the bolt anchors.
6. Attach a bolt lock to the bolt anchors. We recommend Loctite 243.
7. Screw the cap nuts onto the bolt anchors.
8. Tighten the nuts with the tightening torque of the bolt anchors per the manufacturer's instructions.
9. Seal the openings from the mounting surface to the mounting plate with a suitable sealant to prevent the ingress of moisture,
animals and insects.
10. Remove the one transport bracket on the rear of the SICHARGE UC dispenser. Keep the transport plates.
11. Detach the sealing washers, which should be zip tied to the transport plate.
12. Reinstall the bolt with the silicone washers stacked upon one another. Washers are provided loosely in place upon
arrival in the dispenser enclosure.
13. Replace the hardware in the top three holes on the back of the dispenser using the sealing washers and existing bolts.
Detach the sealing washers from the transport bracket.
14. Use one (1) sealing washer and one (1) M8 stainless steel bolt to secure the bracket to the dispenser using the center
weld nut hole and the center slot on the bracket. Tighten the bolt using a torque wrench to 150 in-lbs.
15. Use one (1) sealing washer and one (1) M8 stainless steel bolt in the left weld nut hole, but DO NOT tighten. Repeat for
the right weld nut hole.
16. Using a torque wrench, alternate between the left and right bolts, tightening the bolts in equal increments until they
both are tightened to 150 in-lbs.

5.3 Wall mounting

5.3.1 Mounting the dispenser to the wall

To mount the SICHARGE UC dispenser at the location, you must lift the SICHARGE UC dispenser off the transport pallet. If the
SICHARGE UC dispenser is heavy, transport it to the prepared mounting area using a forklift.
Lifting the SICHARGE UC dispenser
The SICHARGE UC dispenser wall mounting is delivered with mounting rails on the rear of the device.
To lift the SICHARGE UC dispenser off the transport pallet, follow these steps:
1. Mount the shackle into the holes on the right and left of the mounting rail.
2. Attach the shackles to the lifting equipment. Only use suitable and approved lifting equipment.
3. Lift the SICHARGE UC dispenser vertically from the transport pallet.
4. Transport the SICHARGE UC dispenser suspended to the location.