7.4.3 How to Install/Remove Memory Modules

This section explains how to install/remove memory modules.
1
Turn the power off and remove the top cover.
"7.2 Removing and Attaching the Top Cover" (pg.166)
2
Touch a metal part of the server to discharge static electricity.
3
Install or remove memory modules.
• Installing
Insert a memory module properly into the memory slot. The levers close.
If the levers are not closed completely, push them with your fingers.
Check that the memory module is inserted all the way.
• Removing
Open the levers on both ends.
Lever
4
Check that the memory module is inserted all the way.
5
Install the top cover and return the server back into the rack.
"7.2 Removing and Attaching the Top Cover" (pg.166)
6
Initialize the Extended System Configuration Data (ESCD).
On the "8.2.5 Advanced Menu" ( pg.215) of the BIOS Setup Utility, set [Reset Configuration
Data] to [Yes].
7
Store the BIOS settings.
"5.3 Storing the System Setting Information" (pg.140)
Align notch
• Make sure not to open the clips outward too quickly because the memory
module may pop up, which could cause damage.
• An improperly engaged memory module could cause a fire. Do not insert the
memory module on the wrong side.