Maintenance & Notes; Hard Disk Failure Is Detected - Fujitsu PRIMERGY RX200 S2 User Manual

Hide thumbs Also See for PRIMERGY RX200 S2:
Table of Contents

Advertisement

9.10Maintenance & Notes
This section explains the details of the maintenance & Notes.

9.10.1 Hard disk failure is detected

If hard disk failure is detected during POST, the RX200 S2 on-board SCSI array controller stops with
the following message.
Warning!: The array is degraded. Press [Ctrl] [A] to continue after
insert Floppy Disk.
If the controller stops with this message, insert the floppy disk "OnBoard RAID Utility" into the floppy
disk drive of the system, and press the [Ctrl] key and [A] key at once to start up the system from the
floppy disk. The utility automatically starts up. The following message appears on the utility.
Background command progress status for controller 0...
IR Volume 1
Current operation
Volume ID
Volume status
Volume state
Physical disk I/Os
curState: 1
Previous Physical Disk States:
ID0 : Failed
Current Physical Disk States:
ID0 : Online
Fatal ERROR happened. Please call support engineer
As shown here, if the message "Fatal Error happened. Please call support engineer." appears, do not
start up the system. Please contact the maintenance person and system administrator.
Background command progress status for controller 0...
IR Volume 1
Current operation
Volume ID
Volume status
Volume state
Physical disk I/Os
curState: 1
Previous Physical Disk States:
ID0 : Online
Current Physical Disk States:
ID0 : Online
OK. You can boot system.
Please check HDD status after boot
prvState: 0
ID1 : Failed
ID1: Failed
prvState: 3
ID1 : Failed
ID1: Failed
PRIMERGY RX200 S2 User's Guide
: None
: 0
: Enabled
: Degraded
: Not quiesced
: None
: 0
: Enabled
: Degraded
: Not quiesced
9
287

Advertisement

Table of Contents
loading

Table of Contents