Installing Expansion Cards; Where To Install An Expansion Card - Fujitsu PRIMERGY RX200 S2 User Manual

Hide thumbs Also See for PRIMERGY RX200 S2:
Table of Contents

Advertisement

7.5 Installing Expansion Cards

This section explains the types of expansion card, installation procedures, and notes
on expansion cards.

7.5.1 Where to Install an Expansion Card

This server has two PCI slots. Up to two PCI cards can be installed.
The figure below shows the slot locations.
PCISlot1
PCISlot2
[Rear]
■ PCI Slot Specifications
The table below shows the PCI slot specifications.
PCI slot
1
64-bit 133MHz, PCI-X
2
64-bit 66MHz
The PCI slots conform to the PCI local bus specifications (Rev. 2.2).
• Before installation, turn off the server and peripheral devices. Unplug the
power cables from the outlets. Failure to do so may cause electric shock
( "1.4.3 Turning Off the Server" (pg.32)).
• The circuit boards and soldered parts of internal options are exposed. They
can be damaged by static electricity.
Before handling them, first touch a metal part of the server to discharge static
electricity.
• Do not touch the circuitry on boards or soldered parts. Hold the metallic areas
or the edges of the circuit boards.
• Expansion cards are susceptible to static electricity. Place them on conductive
pads or keep them in their packaging as long as they are not necessary.
table: PCI Slot Specifications
Specifications
For a full height, half length, or low profile PCI card
For a low profile PCI card
PRIMERGY RX200 S2 User's Guide